Chamblee, DeKalb County

DUNWOODY EXCHANGE APARTMENTS

4237 N SHALLOWFORD RD ATLANTA, GA 30341

Pool
Latest score
61
May 28, 2026
City
Chamblee
County
DeKalb
Inspections
4

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 28, 2026

Permit/Opening

Score: 6110 violations

2 - self-closing / self-latching gates

15 ptsCorrected: NoRepeat: No

13-202(a)(2) - Entry into the pool area shall have a working self-closing, self-latching gate. Gate was not operational.

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-190(a) - All circulation components must function properly and be maintained at all times. CPO informed me that pumps were not working.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-205(b)(1) - Equipment shall be operated continuously on a 24-hour basis to reach required turnover rate (6)

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a)(7)- Circulation rate did not meet requirement for pool (227)

13 - float line in position

4 ptsCorrected: NoRepeat: No

13-202(i) - Floats should be space no more than 7' apart so to prevent movement.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: Yes

13-190(a) - All circulation system components shall function properly and be maintained in a clean condition. Skimmers were unclean and non-operational.

16 - pool deck: maintained, unobstructed and clean

2 ptsCorrected: NoRepeat: Yes

13-188(h)(4) - Deck shall not retain any standing water greater than 1/8' in depth or greater than 1 sqft for 20 minutes

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: Yes

13-202(m) - Safety rules and regulations shall be easily readable and conspicuously posted. Missing bather load sign.

31 - dressing showers: clean, maintained, hot and cold water available

1 ptsCorrected: NoRepeat: No

13-184(e)(5) - Imminent health hazard due to men's bathhouse not being maintained & operational. (Non-Sanitary)

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-189(c)(1) - Several chemical tests were expired.

Jul 22, 2025

Permit/Opening

Score: 942 violations

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-190 (a) All circulation system components shall function properly and be maintained in a clean condition. Skimmers baskets need to be cleaned out.

16 - pool deck: maintained, unobstructed and clean

2 ptsCorrected: NoRepeat: No

13-188(h)(4) Decks shall not retain any standing water greater than 1/8" in depth or greater than 1 sqft of area for more than 20 minutes.

Jun 25, 2025

Permit/Opening

Score: 812 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g) An operable, hard wired, weatherproof telephone with direct 911 access or capability installed in a conspicuous location shall be readily available at all times within the pool enclosure.

13 - float line in position

4 ptsCorrected: NoRepeat: No

13-202(1) Tightly stretched float line shall be installed across pool along slope-break in pools where depths exceed 5'. Floats spaced no more than depths exceed 7' apart and secured so they won't move.

May 7, 2024

Permit/Opening

Score: 688 violations

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) Pool free chlorine observed at 2.35

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

13-189(c)(1) Pool pH observed at 6.9

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d) Observed one shepherd hook and one life ring without rope. Two sets of safety equipment (Shepherds hook and life ring with rope) required for pools longer than 50 ft.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) Unable to determine turnover rate since no approved flowmeters were installed.

23 - automated controller operational; pumps interlocked

5 ptsCorrected: NoRepeat: No

13-197 (b&c) Timers not allowed in conjunction with pool chlorination or pool pumps.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a)(4) Pools missing all 5 weirs.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

13-202(m) Pool rules not posted inside the pool area. Pool rules missing some required statements. Bather load not noted on pool rules.

24 - piping identified and marked

1 ptsCorrected: NoRepeat: No

13-191(a) Water flow in the pumproom not indicated on the piping.