Brookhaven, DeKalb County

JACKSON SQUARE CONDOMINIUMS

3147 BUFORD HWY NE ATLANTA, GA 30329

Pool
Latest score
81
Jun 10, 2025
City
Brookhaven
County
DeKalb
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 10, 2025

Routine

Score: 812 violations

8 - chemical feeder operational and approved

15 ptsCorrected: YesRepeat: No

13-197(a)- Pool water should be continuously chemically treated with an approved disinfecting agent. observed: Erosion chlorinator did not contain tablets, chlorinator not continuously disinfecting - corrected on site by adding tablets into chlorinator

13 - float line in position

4 ptsCorrected: YesRepeat: No

13-202(l) - Float line must be in position between depths of less than and greater than 5 ft at all times observed: pool float line was removed by community members - corrected on site by CPO

May 22, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 25, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jul 18, 2024

Routine

Score: 6510 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g)- Phone must be operable. Address discrepancy. Emergency operator has the pool address of 3131 Buford Hwy NE but the address on file is 3147 Buford Hwy NE which the address of the condo itself.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1)The free chlorine residual in all parts of the pool shall be maintained at a concentration of no less than 3 ppm. Chlorine was at 0.25ppm

8 - chemical feeder operational and approved

15 ptsCorrected: NoRepeat: No

13-197(a) The water in each pool shall be continuously chemically treated with an approved disinfecting agent. Unable to access equipment room.

9 - filter: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-193 (a) Sand filter tanks shall have an access port for inspection influent and effluent pressure gauges with minimum face size of 2 inches...and an adequately sized in-line backwash sight glass. Could not access equipment room.

10 - pump: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

13-190(a) Pumps shall function properly and be maintained in a clean condition. Could not access equipment room.

19 - adequate turnover rate

5 ptsCorrected: NoRepeat: No

13-190(a) The equipment shall be operated continuously on a 24 basis to obtain the minimum of one turnover every six hours. Unable to access equipment room.

36 - daily recordkeeping: water testing and self inspection performed

5 ptsCorrected: NoRepeat: No

13-202(c) Each pool operator shall maintain and make available for inspection onsite upon request a daily record of operating information. Could not locate daily logbook.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

13-196(a) Each skimmer shall have a properly designed and operating weir. Skimmer baskets were full of debris.

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

13-189(c)(2) Cyanuric acid levels shall not exceed 100ppm. Cyanuric acid was tested at 115ppm.

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: No

13-184(e)(5) Hand rails must be sturdy not too shaky, one of the hand rails was a bit shaky.

Jul 12, 2023

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a): for this 40,000 gallon pool the flow meter shall read 111 gpm to achieve the required 6 hr turnover, I observed 80 gpm