Atlanta, DeKalb County

GABLES EMORY POINT (D1 POOL)

1578 AVENUE PL ATLANTA, GA 30329

Pool
Latest score
79
Jul 16, 2025
City
Atlanta
County
DeKalb
Inspections
2

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jul 16, 2025

Permit/Opening

Score: 797 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

13-202(g) - Emergency phone with direct 911 access should direct calls to Dekalb emergency department, and 911 operators should have the correct facility address on file. observed: 911 operator had address on file different than facility's true address. imminent health hazard.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

13-189(c)(1) - Chlorine levels should be kept between 3 - 10 parts per million & chlorine should only be used in chlorinator. observed: Chlorine reading was 0.26 ppm, and chlorine tablets placed on top of main drains. imminent health hazard.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH shall be kept between 7.2 and 7.8. observed: pH of pool water was 8.3. imminent health hazard.

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

13-202(d) - Each pool shall have required emergency life-saving equipment - a 14-foot non-telescopic Shepard's Hook and a Coast Guard- approved ring buoy attached to throwing rope. observed: no safety equipment observed. imminent health hazard.

32 - operator training certification available onsite and approved

4 ptsCorrected: NoRepeat: No

13-187(c) - A copy of the pool operator's certificate must be posted conspicuously. observed no certificate posted.

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-202(b) - deck shower must be operable and maintained. observed: Deck shower had no running water.

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i) Emergency Action Plan must be available in pool facility with all required sections. observed: Emergency action plan had some required sections, but not all sections. Left EAP template with CPO. imminent health hazard.

Jul 5, 2023

Permit/Opening

Score: 924 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

13-190(a): for a pool of 10,000 gallons the flow meter should read 27 gpm to achieve the required 6 hr turnover; I observed 0 gpm for both return lines

24 - piping identified and marked

1 ptsCorrected: NoRepeat: No

13-190(a): all valves and piping marked in the equipment room shall be clearly labeled and water flow direction shall be indicated; I observed no valves or pipes marked and no water flow indicated

30 - deck/rinse shower maintained

1 ptsCorrected: NoRepeat: No

13-201(b): a shower with tempered water with a range of 70 degrees F to 104 degrees F shall be provided; I observed the deck rinse shower not working

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

13-202(i): a written copy of the emergency action plan (EAP) shall be located to allow for immediate access with all parts filled out; I observed sections of the EAP missing