Fair Oaks, Cobb County

BENTLEY AT MARIETTA THE - POOL

880 S COBB DR SE MARIETTA, GA 30060-3324

Pool
Latest score
80
Jun 5, 2026
City
Fair Oaks
County
Cobb
Inspections
10

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Jun 5, 2026

Routine

Score: 809 violations

4 - water clarity: main drains clearly visible

15 ptsCorrected: NoRepeat: No

Water was turbid, no main drain visible.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Emergency phone not operable. Attempted to connect several times but was never able to reach 911.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Chlorine of 12ppm above acceptable range of 2-10ppm.

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH observed at 7, maintain between 7.2-7.8.

8 - chemical feeder operational and approved

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Leasing office employee stated that pump was broken at time of inspection.

9 - filter: approved, maintained and operating

15 ptsCorrected: NoRepeat: No

Leasing office employee stated that pump was broken at time of inspection.

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

Leasing office employee stated that pump was broken at time of inspection.

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

Skimmers were not pulling water.

34 - inspection report placed in public view

1 ptsCorrected: NoRepeat: No

No inspection report observable. Employee was notified to post one in view.

Apr 8, 2026

Permit/Opening

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: YesRepeat: No

Facility's emergency phone had incorrect pool address; 911 dispatch stated that the call was coming from a mobile phone located on Glover St.

C/A: correct address to 880 S Cobb Dr.

COS: Property manager called Kings 3 to change the address to the correct one; EHS verified by calling through emergency phone

Jul 22, 2025

Re-inspection

Score: 813 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Emergency phone cannot connect to dispatch, fix ASAP

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

pH observed at 7, maintain between 7.2-7.8

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

skimmers not pulling/missing weirs

Jul 16, 2025

Routine

Score: 744 violations

7 - ph between 7.2 and 7.8

15 ptsCorrected: NoRepeat: No

observed pH below 7, maintain between 7.2-7.8

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: Yes

flow meter stuck

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

skimmers not pulling/missing weirs

12 - grab/hand rails, ladders installed and secure

2 ptsCorrected: NoRepeat: Yes

left grab handle loose

May 27, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jun 27, 2024

Re-inspection

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: YesRepeat: No

Observed pH at 7.0 C/A: pH shall be maintained between 7.2 and 7.8. COS: CPO added pH upper; COS to 7.2

May 31, 2024

Permit/Opening

Score: 834 violations

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.07(1)(e ) - (e) water clarity shall be maintained. when standing at the pool's edge at the deep end, the main drain suction outlet covers or a four inch by four inch square marker tile in contrasting color shall be clearly visible. when standing at a spa's e

15 ptsCorrected: NoRepeat: No

Observed cloudy water; could not see the main drain.

C/A: Water clarity shall be maintained; main drains must be visible from the pool deck.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH at 7.0 C/A: pH shall be maintained between 7.2 and 7.8.

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observed the lifesaving ring not attached to the throwing rope; life ring was floating in the pool in disrepair

C/A: Lifesaving ring shall be in good condition with the throwing rope attached

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed pool ladder in disrepair; the step was not secured C/A: all grab handrails and ladders shall be secured

May 1, 2024

Permit/Opening

Score: 783 violations

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(a) - (a) a light, strong pole not less than twelve feet long including body hook.

15 ptsCorrected: YesRepeat: No

Observed no body hook available at the facility C/A: swimming pools shall provide a light, strong pole not less than 12 feet long including body hook. COS: CPO was able to provide body hook

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Observed no flow indicated in the flow meter.

C/A: the flow indicator shall be capable of measuring the flow rate.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Pool ladder and grab handrails are not secure. CPO also stated the ladder was missing the tread.

C/A: grab handrails shall be secure; ladders treads shall have a minimum depth of two inches

Jul 28, 2023

Re-inspection

Score: 698 violations

5 - emergency phone operational and accessible

15 ptsCorrected: NoRepeat: No

Phone not working

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Maintain chlorine at 2-10 ppm

11 - appropriate lifesaving equipment present

15 ptsCorrected: NoRepeat: No

Attach shepherd's hook to pole.

14 - vacuum line protected

5 ptsCorrected: NoRepeat: No

Install self-closing, self-latching vacuum line cover

15 - depth and no diving markers, step marking; installed and contrasting

4 ptsCorrected: NoRepeat: No

Patch around coping as needed

17 - skimmers/gutters maintained and operable

4 ptsCorrected: NoRepeat: No

Skimmer closest to bathhouse not pulling

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

2 ptsCorrected: NoRepeat: No

Post "RISK OF DROWNING: SUPERVISE CHILDREN CLOSELY" SIGN, min. 4" letters

Remark or replace "WARNING: NO LIFEGUARD ON DUTY" sign, min. 4 " letters

Post compliant "Pool Risks" sign, min 1" letters

Post pool occupancy sign, min. 4" letters

37 - other violations of the chapter

1 ptsCorrected: NoRepeat: No

Vacuum pool - bottle cap and trash on floor

Jun 28, 2023

Permit/Opening

Score: 853 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

mergency phone not operational. An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times.

6 - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Choline at 0

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Below 7