Mar 27, 2026
Permit/Opening
4502 CIRCLE 75 PKWY SE ATLANTA, GA 30339-3022
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
skimmer not pulling/missing weir
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter bobber stuck at bottom. Unable to determine turnover rate/flow. CA: Clean or replace flow meter.
Routine
Routine
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
Observed chlorine at 13.5ppm.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter non operable. Clean/replace.
Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.
Skimmer missing weir.
Permit/Opening
Regulation: .17(1)(a)(b) - proper disinfectant level
CHLORINE LEVEL IS TOO HIGH
Regulation: 511-3-5-.11(4)(f) - (f) makeup water shall be supplied through an air gap or other approved backflow prevention device.
WATER LEVEL IS TOO LOW
Routine
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
pH LEVEL TOO LOW
Re-inspection
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
CHLORINE LEVEL OBSERVED AT 0PPM