REX, Clayton County

Rock Creek Sub. Pool

3067 ROCK CREEK DR REX, GA 30273

Pool
Latest score
98
May 20, 2026
City
REX
County
Clayton
Inspections
5

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 20, 2026

Re-inspection

Score: 981 violation

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: YesRepeat: Yes

Observed theoretical peak occupancy and hours of operation not posted. A sign stating the theoretical peak occupancy and hours of operation shall be posted near the entrance of the pool. COS: PIC/CPO filled peak occupancy and hours of operations.

May 7, 2026

Permit/Opening

Score: 816 violations

1 - barrier: pool enclosed/fencing in compliance

Regulation: 511-3-5-.18(11)(b) - (b) openings in the barrier shall not allow passage of a four inch diameter sphere.

15 ptsCorrected: NoRepeat: No

Observed barrier obstructed in two areas of 9ft. Opening in the barrier shall not allow passage four-inch diameter sphere.

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed no emergency phone present. An operable hard-wired emergency phone shall be permanently installed.

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed cL reading of 0 ppm. Free Chlorine level in pool shall be 2.0 to max 10.0

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

Observed pH reading of 8.0. Chemical values shall be pH 7.2 - 7.8

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed no end cap on grab rails. Handrails shall be installed in a way not to be removed.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed 'pool capacity' sign. Sign shall state the theoretical peak occupancy.

May 29, 2025

Permit/Opening

Score: 961 violation

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: YesRepeat: No

Observed missing depth markers and no diving wording in various areas of the pool deck. Advised CPO that depth markers and numbers shall be permanently installed within 25 ft in at least 4-inch lettering and in contrasting color.

May 29, 2024

Permit/Opening

Score: 856 violations

33 - lifeguard training certification available onsite

Regulation: 511-3-5-.18(9) - (9) lifeguards. all owners, managers, or lifeguards, if provided, shall be responsible for the supervision and safety of the pool, spa, or recreational water park. if lifeguards and safety assistants are provided, then they must hold current, nationa

5 ptsCorrected: NoRepeat: No

During time of inspection, observed no lifeguard certificates. Advised CPO all owners, managers, or lifeguards, if provided, shall be responsible for the supervision and safety of the pool, spa, or recreational water park. If lifeguards and safety assistants are provided, then they must hold current, nationally recognized certifications in lifeguarding and a designated title commensurate to the assigned duties. Adult/child/infant CPR and First Aid certifications also must be current. The certificates, or photocopies thereof, shall be maintained at the facility and be available to the local health authority for inspection.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: Yes

Observed missing depth markers in various area of the pool deck. Advised CPO that depth markers and numbers shall be permanently installed within 25 ft in at least 4-inch lettering and in contrasting color.

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

Observed one loose grab rail at 9ft depth marker. Advised CPO handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

2 ptsCorrected: NoRepeat: No

Observed cracks at 9ft grab rail area and multiple cracks on pool deck area. Advised PIC The deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed no theoretical peak occupancy sign at or near front entry gate of pool enclosure. Advised PIC A sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(a) - (a) the words "no diving" and the universal international symbol for “no diving” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that ou

2 ptsCorrected: NoRepeat: No

Observed no universal no diving tiling and 'No Diving' in 4-inch height lettering at all depth markers. Advised PIC The words "No Diving" and the universal international symbol for “NO DIVING” shall be permanently visible at the edge of the deck for water five feet in depth or less, placed only on the deck beside the depth markers, and shall conform to that outlined for depth markers in subsections (3)(a) thru (h) above.

May 30, 2023

Permit/Opening

Score: 942 violations

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(3)(h) - (h) depth markers number and letters shall be tile and four inches minimum in height. numbers shall be of contrasting color to the background on which they are applied.

4 ptsCorrected: NoRepeat: No

Observed missing depth markers and universal "no diving: tile surrounding pool deck area. Advised CPO that depth markers number and letters shall be tile and four inch minimum in height around pool deck area.

16 - pool deck: maintained, unobstructed and clean

Regulation: 511-3-5-.06(1)(i) - (i) a four foot minimum continuous unobstructed deck, which may include the coping, shall be provided around at least 50 percent or more of a spa.

2 ptsCorrected: NoRepeat: No

Observed multiple cracks on pool deck in multiple area. Advised CPO that there shall be unobstructed deck area. Advised to resurface by end of 2023 pool season.