Aug 20, 2025
Re-inspection
7147 MT ZION CIR MORROW, GA 30260
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Re-inspection
Permit/Opening
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Observed front-entry gate not self-closing self-latch at all points. Advised PIC pedestrian access gates shall be self-closing and have a self-latching device. Gates other than pedestrian access gates shall have a self-latching device.
Regulation: .17((1)(c) - proper disinfectant level
Observed CL reading 0. Advised PIC Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0. COS: CPO corrected CL reading to 3.0.
Observed no end caps at bottom of ladders at time of inspection. Advised PIC to place end caps at bottom of ladder at 5ft.
Permit/Opening
Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis
Observed inadequate No Lifeguard On Duty" signage posted on the barrier of the pool. Advised CPO/PIC Where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “WARNING - NO LIFE GUARD ON DUTY and RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY”. Advised CPO/PIC to obtain correct signage.
Re-inspection
Re-inspection
Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates
Observed front-entry gate not self-closing self-latch at far back and midpoint. Advised PIC gates shall be self-closing self-latching.
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Chlorine level observed and reading at zero.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
PH too high was at 8.