Apr 15, 2026
Permit/Opening
1907 S MILLEDGE AVE ATHENS, GA 30605
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Routine
Regulation: 511-3-5-.06(1)(f) - (f) the deck, including coping, shall have a minimum four feet width of continuous, unobstructed walking area maintained at all times unless otherwise allowed in the chapter.
water fount not present
Permit/Opening
drinking fountain not provided
Permit/Opening
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
pH measured 7.0, maintain pH at 7.2-7.8
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Chlorine concentration below 2-10ppm range. Repeat
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
pH at 8.0, Maintain pH at 7.2-7.8.
Permit/Opening
Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;
Emergency phone not operating.
Regulation: .17((1)(c) - proper disinfectant level
Chlorine level less than 2ppm.
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
Flow meter stuck - not operating.
Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis
Sign for NO LIFEGUARD not present. Must read as: WARNING - NO LIFEGUARD ON DUTY - RISK OF DROWNING - SUPERVISE CHILDREN CLOSELY.
Regulation: 511-3-5-.18(12)(c) - (c) the same sign in subsection (b) above or an additional sign will state under the heading “pool risks” the following items in clearly legible letters at least one inch high:
Sign for Pool Risks in 1 inch lettering.
Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.
Sign for PEAK OCCUPANCY 37.
Permit/Opening