ACWORTH, Cherokee County

Josh Powell Camp

5242 WADE GREEN RD ACWORTH, GA 30102

Pool
Latest score
100
May 15, 2026
City
ACWORTH
County
Cherokee
Inspections
9

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 15, 2026

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Jul 22, 2025

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter operating at 70 GPM, increase to 116.

Jul 11, 2025

Routine

Score: 851 violation

5 - emergency phone operational and accessible

Regulation: 511-3-5-.23(5)(h) - (h) absence of required lifesaving equipment on the deck or an emergency phone;

15 ptsCorrected: NoRepeat: No

Emergency Phone Not Working - Repair

May 14, 2025

Routine

Score: 951 violation

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Flow Meter at 70 increase to 100

Jul 30, 2024

Routine

Score: 912 violations

28 - flow meter: appropriate range and location

5 ptsCorrected: NoRepeat: No

Flow meter at 70 - increase to 116 to meet turnover rate

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

Cya greater than 100 - maintain below 90

May 13, 2024

Re-inspection

Score: 893 violations

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

The flowmeter was reading 47 GPM at time of inspection. Must be at least 116 to meet turnover rate.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid level was greater than 90ppm

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

There is no sign stating the pool’s bathing load in at least 4-inch letters or a sign stating the pools hours of operation posted at or near the pool’s entrance.

May 6, 2024

Permit/Opening

Score: 961 violation

35 - operator facility inspections performed; written documentation

Regulation: 511-3-5-.22(6) - (6) written documentation of the operator’s visits must be available at the pool facility. at a minimum, the written record must indicate the condition of the following items:

4 ptsCorrected: NoRepeat: No

Provide documentation.

Jul 31, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

Jun 2, 2023

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Flow rate at 80 gpm. Must be 116 gpm.