ACWORTH, Cherokee County

Waldan Pond

450 WALDAN CIR ACWORTH, GA 30102

Pool
Latest score
77
May 5, 2026
City
ACWORTH
County
Cherokee
Inspections
11

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

May 5, 2026

Permit/Opening

Score: 773 violations

11 - appropriate lifesaving equipment present

Regulation: 511-3-5-.18(10)(b) - (b) a minimum one-fourth inch diameter throwing rope one and one-half times the maximum width of the pool or fifty feet in length, whichever is less, to which has been firmly attached a ring buoy with an outside diameter of approximately fifteen inch

15 ptsCorrected: NoRepeat: No

Observed life ring with out a rope. Must have a rope for the life ring which is one and half times the width of the pool or 50feet which ever is greater.

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Missing weir in the skimmer.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Must install effluent pressure gauge.

Aug 22, 2025

Routine

Score: 922 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid greater than 100ppm. Must be below 90ppm.

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Must install effluent pressure gauge.

May 21, 2025

Permit/Opening

Score: 961 violation

26 - gauge(s) in proper location; sight glass installed

Regulation: 511-3-5-.07(4)(a) - (a) a pressure or vacuum gauge or other means of indicating system condition shall be provided in the circulation system in an easily readable location.

4 ptsCorrected: NoRepeat: No

Must install effluent pressure gauge.

Aug 30, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Aug 30, 2024

Re-inspection

Score: 851 violation

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH is less than 7.0. Must be between 7.2 and 7.8

Aug 23, 2024

Re-inspection

Score: 851 violation

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Observed no chlorine in the pool.

Aug 22, 2024

Routine

Score: 851 violation

6 - proper disinfectant level

Regulation: .17((1)(c) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

No chlorine in the pool.

May 24, 2024

Re-inspection

Score: 961 violation

17 - skimmers/gutters maintained and operable

Regulation: 511-3-5-.11(3)(d) - (d) each skimmer shall have a weir that adjusts automatically to variations in water level over a minimum range of four inches.

4 ptsCorrected: NoRepeat: No

Missing weir in the skimmer.

May 22, 2024

Routine

Score: 852 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

No chlorine in the pool.

7 - ph between 7.2 and 7.8

Regulation: 511-3-5-.17(2) - (2) chemical values: ph

15 ptsCorrected: NoRepeat: No

pH is greater than 8.0. Must be between 7.2 and 7.8

Jun 26, 2023

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 25, 2023

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.