Jun 6, 2024
Permit/Opening
5 - emergency phone operational and accessible
Observed emergency phone not operable at time of inspection. CA: An operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all times. The emergency phone shall be capable of connecting to 911 and electronically transferring an automatic number identification and automatic locator identification of the pool emergency phone to the public safety answering point, if available. A 911 sign or the names and phone numbers of the nearest available police, fire, ambulance service or rescue unit shall be posted nearby.
6 - proper disinfectant level
Regulation: .17((1)(c) - proper disinfectant level
Observed free chlorine level at 1.21ppm. RCA: The minimum required for an outdoor pool is 2.0ppm. This must be corrected prior to opening the pool.