Routine
155 GENERAL LEE DR RINGGOLD, GA 30736
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Routine
Routine
Permit/Opening
.16(7)Pool not supplied with an accurate and reliable water quality testing device capable of measuring any agent that is introduced into the water of the pool. CA - Discussed with CPO that test kit reagents were out of date and she ordered new test kit
Routine
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
OBSERVED NO FLOAT IN FLOW METER OR FLOW METER STUCK AND UNABLE TO PROVIDE ACCURATE READING. CA: RESPONSIBLE PERSON WILL HAVE FLOW METER REPAIRED OR REPLACED.
Permit/Opening
Routine
Regulation: 511-3-5-.22(12) - (12) a safety self-inspection shall be conducted daily by the trained operator or responsible person and documented on a log sheet.
OBSERVED POOL LOG SHEET NOT HAVING BEEN LOGGED DAILY. CA: DISCUSSED WITH CPO THAT ALL DAILY POOL TESTS WILL BE LOGGED ON LOG SHEET.
Re-inspection
Re-inspection
Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin
OBSERVED BROMINE LEVEL BELOW MINIMUM REQUIRED LEVEL OF 3.0 PPM. OBSERVED BROMINE LEVEL AT 1.3 PPM. CA: RESPONSIBLE PERSON CLOSED POOL.
Regulation: 511-3-5-.23(5)(b) - (b) during operation, the ph is less than the minimum or more than the maximum levels allowed in dph rule 511-3-5-.l7.
OBSERVED PH BELOW MINIMUM REQUIRED LEVEL OF 7.2. OBSERVED PH AT 6.9. CA: RESPONSIBLE PERSON CLOSED POOL.
Permit/Opening
Regulation: 511-3-5-.22(11) - (11) if the water test results are not in compliance with dph rule 511-3-5-.17, the operator shall close the pool, record findings, and make the necessary adjustments to the water chemistry to comply with the chapter. the chemicals used and amounts s
OBSERVED TEST KITS AT FACILITY UNABLE TO PROVIDE ACCURATE AND RELIABLE READINGS. CA: FACILITY SHALL ORDER NEW TEST KIT THAT IS ACCURATE AND RELIABLE.