Apr 30, 2026
Permit/Opening
28 - flow meter: appropriate range and location
Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from
At time of inspection, there was no flow meter installed. Install a flow meter.
21 - cyanuric acid level not exceeding maximum
Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br
At time of inspection, the cyanuric acid (CYA) registered at 108 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, to ensure that CYA is below 90 ppm.