Apr 1, 2026

Re-inspection

Score: 942 violations

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the cyanuric acid (CYA) level registered at 132 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, to ensure that CYA is below 90 ppm.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "WARNING: NO LIFEGUARD ON DUTY..." signs are missing. PIC has ordered the signs and will have them posted ASAP.

Mar 27, 2026

Re-inspection

Score: 794 violations

9 - filter: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

At time of inspection, there appears to be air in the system, causing the pump to intermittently lose prime. This is causing the flow to rise and fall. For this reason, the pump and filter are unable to continuously function as intended. Maintenance is attempting to bleed the air out through the filter, and will continue to troubleshoot. The CPO is scheduled to return to work next week.

10 - pump: approved, maintained and operating

Regulation: 511-3-5-.23(5)(c ) - (c) the pump, automatic disinfectant equipment, or other equipment necessary for continuous filtration and disinfection of the swimming pool, spa, or recreational water park attraction is not working or is unable to maintain adequate turnover rate.

15 ptsCorrected: NoRepeat: No

At time of inspection, there appears to be air in the system, causing the pump to intermittently lose prime. This is causing the flow to rise and fall. For this reason, the pump and filter are unable to continuously function as intended. Maintenance is attempting to bleed the air out through the filter, and will continue to troubleshoot. The CPO is scheduled to return to work next week.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: Yes

At time of inspection, the cyanuric acid (CYA) level registered at 112 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water, when he returns next week, to ensure that CYA is below 90 ppm.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: Yes

At time of inspection, the "WARNING: NO LIFEGUARD ON DUTY..." signs are missing. PIC is ordering the signs and will post them at each entrance to the pool.

Mar 24, 2026

Permit/Opening

Score: 744 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

At time of inspection, the free chlorine level registered at 0.18 ppm (free chlorine must be within 2.00 - 10.00 ppm). PIC will have the chlorinator adjusted.

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

At time of inspection, the flow meter registered the flow rate at 55 GPM (flow rate should be 113 GPM or greater). The pressure gauge on the filter registered at 32 psi, indicating that the filter needs to be backwashed, which should aid in increasing the flow rate.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 106 ppm (CYA must be 90 ppm or less). Some water should be drained and replaced with fresh water, until CYA is below 90 ppm.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(12)(b) - (b) where no lifeguard is on duty, a sign or signs shall be placed in clear view at or near the entrance to the pool and shall state in clearly legible letters at least four inches high “warning - no life guard on duty and risk of drowning - supervis

2 ptsCorrected: NoRepeat: No

At time of inspection, the "WARNING: NO LIFEGUARD ON DUTY..." sign is missing. Order signs and install near pool entrances. Ensure lettering is at least 4 inches high.

Sep 23, 2025

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Sep 15, 2025

Routine

Score: 812 violations

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

At time of inspection, the emergency phone is not functioning - the light comes on, but no sound is heard. CPO contacted the phone company and they are troubleshooting. The pool is currently closed and locked and must remain so, until the emergency phone is fully operational AND the pool has passed re-inspection.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

At time of inspection, the cyanuric acid (CYA) level registered at 96 ppm (CYA must be 90 ppm or less). CPO will drain some water and add some fresh water to ensure that CYA stays below 90 ppm going forward.

Mar 11, 2025

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

Oct 18, 2024

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Sep 10, 2024

Routine

Score: 852 violations

4 - water clarity: main drains clearly visible

Regulation: 511-3-5-.23(5)(d) - (d) the water turbidity is such that the suction outlet/main drain cover or a standard white marker tile on the bottom of the deepest portion of the pool cannot be seen.

15 ptsCorrected: NoRepeat: No

At time of inspection, the water is excessively cloudy. The CPO has the pool closed and is working on remediating the pool. CPO states he will keep the pool closed, until it has passed re-inspection.

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

At time of inspection, the free chlorine level is less than the minimum disinfection requirement (observed at 0.24 ppm and must be at least 2.00 for this type of pool). The CPO has the pool closed and is working on remediating the pool. CPO states he will keep the pool closed, until it has passed re-inspection.

Mar 1, 2024

Permit/Opening

Score: 981 violation

12 - grab/hand rails, ladders installed and secure

Regulation: 511-3-5-.06(3)(f)1. - 1. handrails, if removable, shall be installed in such a way that they cannot be removed without the use of tools.

2 ptsCorrected: NoRepeat: No

At time of inspection, observed loose handrail at shallow end of pool. CPO states he plans to tighten the handrail ASAP, before opening the pool on Monday.