Jun 9, 2026
Routine
6-1A - proper cold holding temperatures
Regulation: 511-6-1.04(6)(f) - time/temperature control for safety; cold holding (p)
Observed beef and two types of chicken with internal temperature 61°F, 54°F, and 62°F, respectively. Potentially hazardous foods must be held at or below 41°F until service. Thawing must be either done under refrigeration, or fully submerged in cool running water. The internal temperature during thawing shall exceed 41°F. Additionally, food must be properly cooled after portioning. Do not pull multiple items out at the same time. Instead, finish with one item, return it to the cooler, then work with the next item. COS - out of temp foods discarded and waste recorded.
17D - adequate ventilation and lighting; designated areas used
Regulation: 511-6-1.07(3)(f) - lighting intensity, adequate in food prep, storage & service areas (c)
Lighting inadequate in walk-in coolers. Needs to be 10 foot candles, measured 30" above floor. Also no items should be stored in front of light.