Mar 28, 2025
Permit/Opening
399 PLANTATION WAY MACON, GA 31210
Inspection scores over time for this facility.
Georgia inspection history is score-based, with violations grouped under each recorded inspection.
Permit/Opening
Permit/Opening
Permit/Opening
Regulation: .17((1)(c) - proper disinfectant level
Observed no chlorine present in the pool. (c) Free Chlorine level in pools using cyanuric acid or a stabilized chlorine product; Minimum 2.0 Ideal 2.0-5.0 Maximum 10.0. EHS informed the community manager of the water chemistry issues.
Regulation: 511-3-5-.17(2) - (2) chemical values: ph
Observed the pool PH level at 8. 2) Chemical Values: pH 7.2 7.4-7.6 7.8 Alkalinity (buffering), 60 ppm 80-100 halogens compounds with high pH 180 ppm as CaC03 100-120 halogen compounds with low pH Calcium hardness, ppm, CaCo3 150 200-400 to balance water 1000.EHS informed the community manager of the water chemistry issue.
Regulation: 511-3-5-.22(2) - (2) the trained operator shall have a current certificate showing completion of an approved operator training course. a copy or the original certificate or documentation shall be available onsite for inspection by the health authority.
Observed facility without CPO guidance as of today per the community manager; CPO quit. (2) The trained operator shall have a current certificate showing completion of an approved operator training course. A copy or the original certificate or documentation shall be available onsite for inspection by the Health Authority. The community manager is aware of the need to find another certified pool operator.
Permit/Opening