Jun 8, 2026

Re-inspection

Score: 1000 violations
No violations recorded for this inspection.

Jun 1, 2026

Permit/Opening

Score: 824 violations

2 - self-closing / self-latching gates

Regulation: 511-3-5-.18(11)(h) - (h) access gates shall also comply with the requirements of this rule and shall be equipped to accommodate a locking device. barrier gates shall open away from the pool in facilities constructed after adoption of this chapter. pedestrian access gates

15 ptsCorrected: NoRepeat: No

Observed entry/exit gate that does not self close and self latch. Exterior door leading to the pool deck also does not self close and self latch. CA: CPO will correct

5 - emergency phone operational and accessible

Regulation: 511-3-5-.18(10)(c ) - (c) an operable, hard-wired, conventional telephone line or continuous powered source, weatherproof emergency phone shall be permanently installed in a conspicuous location within the pool enclosure and must be readily available to bathers at all tim

15 ptsCorrected: NoRepeat: No

Observed emergency phone connect to Floyd county 911 and physical address on file is for the Kid Stop location in Rome. CA: CPO will correct so that the emergency phone connects directly to Bartow 911.

22 - signs: peak occupancy/pool/spa/signs legible and in clearview

Regulation: 511-3-5-.18(13)(c) - (c) a sign shall be posted stating the hours of operation in clear view near the entrance and shall state the theoretical peak occupancy.

2 ptsCorrected: NoRepeat: No

Observed no signage to indicate peak occupancy. CA: CPO will add to the existing signage.

24 - piping identified and marked

Regulation: 511-3-5-.08(6) - (6) all piping shall be marked with directional arrows as necessary to determine flow direction. all piping in the equipment room shall be permanently identified by its use and the pool and or aquatic feature it serves.

1 ptsCorrected: NoRepeat: No

Observed no directional arrows marked on piping. CA: CPO will add arrows.

Jun 30, 2025

Routine

Score: 1000 violations
No violations recorded for this inspection.

May 22, 2025

Permit/Opening

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid level reading 142ppm. CA: Informed CPO that cyanuric acid must not exceed the maximum of 90ppm.

May 30, 2024

Permit/Opening

Score: 1000 violations
No violations recorded for this inspection.

May 31, 2023

Permit/Opening

Score: 773 violations

6 - proper disinfectant level

Regulation: 511-3-5-.23(5)(a) - (a) during operation, disinfectant levels are less than the minimum level specified in dph rule 511-3-5-.17. if the level of the disinfectant used is not specified in dph rule 511-3-5-.17, the disinfectant must be approved and kept at levels determin

15 ptsCorrected: NoRepeat: No

Observed chlorine reading of 0.27. CA: Informed PIC that chlorine levels must range from 1.0-10. Pool closed.

15 - depth and no diving markers, step marking; installed and contrasting

Regulation: 511-3-5-.18(4) - (4) depth markers for spas. public spas shall have permanent depth markers with numbers and letters a minimum of four inches high plainly and conspicuously visible from all obvious points of entry and in conformance with subsections (a) thru (f) belo

4 ptsCorrected: NoRepeat: No

Observed no tile depth markers on pool deck. CA: Depth markers must be tiled.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Observed cyanuric acid level reading "Hi". CA: Informed PIC that cyanuric acid must range between 30-50, Maximum: 90.