Winder, Barrow County

Holiday Inn Express & Suites

775 EXCHANGE CIR BETHLEHEM, GA 30620

Pool
Latest score
96
Aug 7, 2025
City
Winder
County
Barrow
Inspections
6

Score history

Inspection scores over time for this facility.

Inspection history

Georgia inspection history is score-based, with violations grouped under each recorded inspection.

Aug 7, 2025

Re-inspection

Score: 961 violation

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid level is at 100ppm and is over the maximum allowed (90ppm). Facility has decided to voluntarily close and correct all violation. Once all violations are corrected facility will call to schedule a reinspection. CA - Cyanuric acid levels must be within the appropriate range (below 90ppm).

Jul 24, 2025

Routine

Score: 763 violations

6 - proper disinfectant level

Regulation: .17(1)(a)(b) - proper disinfectant level

15 ptsCorrected: NoRepeat: No

Free chlorine concentration is 25ppm and is above the maximum allowed (10ppm). CA - Free chlorine concentration must be within the appropriate range (2-10ppm). Facility will call to schedule a reinspection and has decided to voluntarily close until Barrow Co. Environmental Health Dept. conducts a reinspection and allows facility to reopen pool.

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter is stuck on bottom. CA - Person in charge has agreed to have flow meter replaced.

21 - cyanuric acid level not exceeding maximum

Regulation: 511-3-5-.17(4) - (4) stabilizer (if used) cyanuric acid,ppm ideal: 30-50 maximum: 90 comments: if stabilizer is: too high: - may reduce chlorine efficacy too low: - chlorine residual rapidly destroyed by sunlight note: stabilizer is not needed in indoor or br

4 ptsCorrected: NoRepeat: No

Cyanuric acid level is at 100ppm and is over the maximum allowed (90ppm). Facility has decided to voluntarily close and correct all violation. Once all violations are corrected facility will call to schedule a reinspection. CA - Cyanuric acid levels must be within the appropriate range (below 90ppm).

Apr 16, 2025

Permit/Opening

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

flow meter stuck. CA: Have flow meter repaired or replaced to verify adequate turnarover of 77gpm

Aug 12, 2024

Routine

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Pool turnover rate not adequate. CA - Increase turnover rate to appropriate amount of 77gpm.

May 28, 2024

Permit/Opening

Score: 951 violation

28 - flow meter: appropriate range and location

Regulation: 511-3-5-.07(4)(b) - (b) a flow meter measuring the rate of flow through the filter system with an appropriate range readable in gallons per minute (gpm) and accurate within ten percent actual flow shall be provided. the flow indicator shall be capable of measuring from

5 ptsCorrected: NoRepeat: No

Flow meter is stuck on bottom. CA - Person in charge has agreed to have flow meter replaced or repaired.

Jul 18, 2023

Routine

Score: 951 violation

19 - adequate turnover rate

Regulation: 511-3-5-.07(1)(a) - (a) the equipment for a swimming pool shall be of adequate size to turn over the entire pool water capacity. the turnover rate for pools constructed after the adoption of this chapter shall not exceed the sum of one and one-half times the average wat

5 ptsCorrected: NoRepeat: No

Pool turnover rate not adequate.